C18 Guard Columns

C18 Guard Columns
Line drawing of a column
SKU: 186005491
Category: Columns
XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
Part Number: 186005491
  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    80 C (Low pH) / 45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186007206
Category: Columns
Waters XSelect CSH130 C18 5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications
Part Number: 186007206
  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Guard Column

  • Inner Diameter

    30 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186004136
Category: Columns
ACQUITY UPLC HSS C18 SB columns are used for low pH separations that contain complex mixtures of basic and non-basic compounds. ACQUITY HSS C18 SB columns give you alternative analyte selectivity compared to most modern, high coverage, fully endcapped C18 stationary phases. ACQUITY HSS C18 SB columns are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186004136
  • UNSPSC

    41115700

  • Brand

    ACQUITY UPLC

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    8.5 %

  • Bonding Technology

    C18 SB

  • Chemistry

    C18

  • Endcapped

    No

  • Endfitting Type

    Direct-Connect

  • Format

    VanGuard Pre-column

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    1.8 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    High

  • Surface Area

    230

  • System

    UHPLC, UPLC

  • Particle Technology

    HSS

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Temperature Limits

    45

  • Maximum Pressure

    18000 psi (1240 Bar)

SKU: 186008506
Category: Columns
CORTECS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. CORTECS T3 analytical columns containing 2.7 µm sorbent particles. 
Part Number: 186008506
  • UNSPSC

    41115709

  • Brand

    CORTECS

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    4.7 %

  • Bonding Technology

    T3

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    VanGuard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.7 µm

  • Particle Substrate

    Silica

  • Pore Size

    120 Å

  • Silanol Activity

    Low

  • Surface Area

    100

  • System

    UHPLC, UPLC

  • Particle Technology

    Solid Core

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

Line drawing of a column
SKU: 186008507
Category: Columns
CORTECS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. CORTECS T3 analytical columns containing 2.7 µm sorbent particles. 
Part Number: 186008507
  • UNSPSC

    41115709

  • Brand

    CORTECS

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    4.7 %

  • Bonding Technology

    T3

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Parker-style

  • Format

    VanGuard Cartridge

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    2.7 µm

  • Particle Substrate

    Silica

  • Pore Size

    120 Å

  • Silanol Activity

    Low

  • Surface Area

    100

  • System

    UHPLC, UPLC

  • Particle Technology

    Solid Core

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • eCord

    Yes

SKU: 186008508
Category: Columns
CORTECS T3 VanGuard Pre-Columns are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This Pre-Column is optimized to protect all CORTECS UPLC T3 analytical columns containing 1.6 µm sorbent particles. 
Part Number: 186008508
  • UNSPSC

    41115709

  • Brand

    CORTECS

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    4.7 %

  • Bonding Technology

    T3

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Direct-Connect

  • Format

    VanGuard Pre-column

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    1.6 µm

  • Particle Substrate

    Silica

  • Pore Size

    120 Å

  • Silanol Activity

    Low

  • Surface Area

    100

  • System

    UHPLC, UPLC

  • Particle Technology

    Solid Core

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

Line drawing of a column
SKU: 186005418
Category: Columns
XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
Part Number: 186005418
  • UNSPSC

    41115709

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC Preparative

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    80 C (Low pH) / 45 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001001
Category: Columns
XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001001
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    16 %

  • Bonding Technology

    MS C18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001007
Category: Columns
XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information
Part Number: 186001007
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001006
Category: Columns
XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information
Part Number: 186001006
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001002
Category: Columns
XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001002
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    16 %

  • Bonding Technology

    MS C18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001034
Category: Columns
XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001034
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    16 %

  • Bonding Technology

    MS C18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186003699
Category: Columns
Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186003699
  • UNSPSC

    41115709

  • Brand

    Atlantis

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    14 %

  • Bonding Technology

    T3

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    Medium

  • Surface Area

    330

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    45

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001036
Category: Columns
XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information
Part Number: 186001036
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    15 %

  • Bonding Technology

    Shield RP18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186003695
Category: Columns
Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186003695
  • UNSPSC

    41115709

  • Brand

    Atlantis

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    14 %

  • Bonding Technology

    T3

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    Medium

  • Surface Area

    330

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    45

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186002300
Category: Columns
Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186002300
  • UNSPSC

    41115709

  • Brand

    Atlantis

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    12 %

  • Bonding Technology

    dC18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    10 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    Medium

  • Surface Area

    330

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    3 pH

  • pH Range Max

    7 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    45

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186001847
Category: Columns
Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.
Part Number: 186001847
  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    8.5 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    19 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Silica

  • Pore Size

    300 Å

  • Silanol Activity

    Low

  • Surface Area

    335

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    45

  • Maximum Pressure

    6000 psi (415 Bar)

SKU: 186006939
Category: Columns
Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186006939
  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    ACQUITY UPLC

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Endfitting Type

    Direct-Connect

  • Format

    VanGuard Pre-column

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC, UPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

Line drawing of a column
SKU: 186006944
Category: Columns
Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186006944
  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    3 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    No

  • Endfitting Type

    Direct-Connect

  • Format

    VanGuard Pre-column

  • Inner Diameter

    2.1 mm

  • Length

    5 mm

  • Separation Mode

    Reversed Phase

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    2.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    UHPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

Line drawing of a column
SKU: 186006954
Category: Columns
Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Please note: this guard column requires a 2.1 x 10 mm Universal Sentry Guard Holder, (P/N WAT097958)
Part Number: 186006954
  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    2 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Sentry Guard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186006958
Category: Columns
Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Please note: this guard column requires 4.6 x 20 mm Universal Sentry Guard Holder, (P/N WAT046910)
Part Number: 186006958
  • UNSPSC

    41115709

  • Application

    Peptide

  • Brand

    XSelect

  • Product Type

    Guards

  • Units per Package

    2 pk

  • Carbon Load

    15 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Sentry Guard Cartridge

  • Inner Diameter

    4.6 mm

  • Length

    20 mm

  • Separation Mode

    Reversed Phase

  • Molecular Weight Range Min

    1000

  • Molecular Weight Range Max

    15000

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    130 Å

  • QC Tested

    Peptide

  • Silanol Activity

    Low

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    CSH

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186002536
Category: Columns
SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002536
  • UNSPSC

    41115709

  • Brand

    SunFire

  • Product Type

    Guards

  • Units per Package

    2 pk

  • Carbon Load

    16 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Sentry Guard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    Low

  • Surface Area

    340

  • System

    HPLC

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186002530
Category: Columns
SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002530
  • UNSPSC

    41115709

  • Brand

    SunFire

  • Product Type

    Guards

  • Units per Package

    2 pk

  • Carbon Load

    16 %

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Sentry Guard Cartridge

  • Inner Diameter

    2.1 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Particle Substrate

    Silica

  • Pore Size

    100 Å

  • Silanol Activity

    Low

  • Surface Area

    340

  • System

    HPLC

  • USP Classification

    L1

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

Line drawing of a column
SKU: 186006903
Category: Columns
30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.
Part Number: 186006903
  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Guards

  • Units per Package

    1 pk

  • Carbon Load

    16 %

  • Bonding Technology

    MS C18

  • Chemistry

    C18

  • Endcapped

    Yes

  • Format

    Prep Guard Cartridge

  • Inner Diameter

    30 mm

  • Length

    10 mm

  • Separation Mode

    Reversed Phase

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Particle Substrate

    Hybrid

  • Pore Size

    125 Å

  • Silanol Activity

    Low

  • Surface Area

    175

  • System

    HPLC Preparative

  • USP Classification

    L1

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Technique

    LC, LC/MS

  • Temperature Limits

    60

  • Maximum Pressure

    6000 psi (415 Bar)

Related Categories