BioResolve RP mAb Polyphenyl VanGuard Cartridge, 450Å, 2.7 µm, 2.1 mm X 5 mm Columns contain 2.7 µm superficially-porous-silica particles having an average pore diameter of 450Å. The particles are functionalized with a proprietary polyphenyl bonding process that was specifically designed for LC or LC-MS analyses of intact IgG monoclonal antibodies and their fragments. This Part Number contains (3) VanGuard Cartridges.

Note: The VanGuard Universal Cartridge Holder (p/n: 186007949) is required for use with these replaceable cartridges. p/n: 176004212 contains (3), 2.1 x 5mm VanGuard Cartridges as well as an included VanGuard Universal Cartridge Holder (p/n: 186007949).

This guard column is compatible with:

p/n: 186008944 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 50 mm

p/n: 186008945 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 100 mm

p/n: 186008946 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 150 mm

p/n: 186008948 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 50 mm

p/n: 186008949 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 100 mm

p/n: 186008950 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 150 mm

p/n: 176004156 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 50 mm w/ Standards

p/n: 176004157 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 100 mm w/ Standards

p/n: 176004158 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 2.1 mm X 150 mm w/ Standards

p/n: 176004162 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 50 mm w/ Standards

p/n: 176004163 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 100 mm w/ Standards

p/n: 176004164 BioResolve RP mAb Polyphenyl Column, 450Å, 2.7 µm, 3 mm X 150 mm w/ Standards

Spécifications

  • Mode de séparation

    Phase inverse

  • Temperature Limits

    90 C

  • Maximum Pressure

    10000 psi (689 Bar)

  • Granulométrie

    2.7 µm

  • Taille des pores

    450 Å

  • QC Tested

    Protein

  • Système

    HPLC, UHPLC, UPLC

  • Classification USP

    L11

  • UNSPSC

    41115709

  • Gamme

    BioResolve

  • Type de produit

    Gardes

  • Units per Package

    3 pk