Waters Fraction Manager - Analytical

Waters Fraction Manager - Analytical

Uniquely designed to accurately collect fractions from high-efficiency UPLC separations

Uniquely designed to accurately collect fractions from high-efficiency UPLC separations

Efficiency gains realized by ultra-performance liquid chromatography (UPLC) and ultra-high-performance liquid chromatography (UHPLC) separations often get lost with traditional slow-speed, high-volume HPLC-grade fraction collectors.

Minimize fraction loss and carryover to better manage low volume peaks and efficiently collect small amounts of material for further assays with the Waters Fraction Manager (WFM-A), an analytical-scale fraction collector for UPLC systems. Waters has designed the WFM-A to provide high purity and recovery, confidently minimize sample loss, and reduce carryover of your complex mixtures and precious samples.

Waters Fraction Manager - Analytical Waters Fraction Manager - Analytical

Specifications

Operating UPLC flow range

0.1 to 2.2 mL/min with standard needle

Operating HPLC flow range

0.1 to 5.0 mL/min with high flow needle

pH operating range

pH 2–12

Internal delay volume

13.6 µL*

Maximum back pressure

<300 psi

Needle move time

0.7 s Vessel to vessel with needle above vessel

1.1 s Vessel to vessel with needle into bottom of vessel

Carryover

<0.15% with rinse enabled

Fraction compartment temperature

Range 4.0–40.0 °C, settable in 0.1 °C increments; maintains 19.0 °C below ambient with a tolerance range between -2.0 °C–4.0 °C

Primary wetted material

MP35N, PEEK, Teflon, DLC, and Tefzel

Integrated leak management

Leak sensor as standard, and safe leak handling

*Under specific conditions

Fraction simulation

Model and optimize collection parameters using chromatogram data

Needle rinse

Rinse needle before injection or at the end of a peak per user specified duration

Needle flush

Flush needle volume into the last vessel at the end of a time window, after a collection state change, or at end of a peak

Plate type (2 plates)

Capacity

Total capacity

96-well plate (shallow or deep)

96 wells

192 wells

2 mL vial plate

48 vials

96 vials

4 mL vial plate

24 vials

48 vials

10 mL vial plate

15 vials

30 vials

Eppendorf tube plate (0.65 mL)

48 vials

96 vials

Eppendorf tube plate (1.5 mL)

24 vials

48 vials

Audible noise

<60 db

Operating temperature

Range 4–40 °C

Storage temperature

-40 °C–60 °C

Humidity

20% to 80% non-condensing

External control

Empower® or MassLynx® Software with FractionLynx™ Application Manager

External communications

Ethernet interfacing via RJ45 connection to host PC

Event inputs/outputs

Inject start, auxiliary output

Voltage

90 to 264 VAC

Frequency

47 to 63 Hz

Width

34 cm (13.5 inches)

Height

27 cm (10.75 inches)

Depth

71 cm (28 inches)

Weight

20 kg (45 lbs)

Overview

  • Designed specifically to collect the narrow and closely eluting compounds found with UPLC separations.
  • Developed on the ACQUITY UPLC platform, the industry standard for innovative and reliable technology, the WFM-A integrates seamlessly into all Waters analytical UPLC/UHPLC and HPLC systems.
  • Biocompatible when paired with ACQUITY Premier System with MaxPeak High Performance Surfaces (HPS) Technology collection needle and inert flow path to cool fractions for biopharma applications.

Recommended Use: Ideal for accurately collecting fractions in pharmaceutical, biopharmaceutical, impurity isolation, metabolite, and natural product applications.


Features Header

Features Header






Purposefully designed for high-efficiency, high-purity collections

The WFM-A overcomes the peak purity challenges of typical fraction collectors and includes features like:

  • Low peak dispersion: The low volume, rapid switching valve reduces dispersion and allows the precise collection of narrow UPLC peaks.
  • Sample recovery: To further increase recovery of your smallest fractions, the advanced needle design focuses flow and prevents precious sample droplets from forming on the tip.
  • Temperature control: The sample compartment is precisely controlled at a range of 4–40 °C to accommodate thermally labile samples.
  • Biocompatibility: The WFM-A inert flow path allows effortless integration into your UPLC or HPLC system, accommodating all biomolecule applications.
  • System versatility: Specialized needles are designed to accurately dispense fractions for UPLC flow rates of 2 mL/min or higher HPLC flow rates of 5 mL/min.

Novel design for less carryover, maximum recovery, and higher purity

Fraction purity is a major concern when performing analytical fraction collection due to the inherent small volume application work. Classic fraction collector designs trap a portion of the fraction in the dispensing tube when the valve closes. The trapped portion is then collected with the next fraction when it is dispensed typically referred to as “crosstalk.”

The innovative fluidic design of the WFM-A minimizes carryover risk. The syringe can be programmed to dispense a small amount of rinse solvent through the dispense needle after a fraction is collected. This rinse can be directed either to waste, or into the current fraction vessel increasing fraction purity by reducing crosstalk.


Better peak integrity with minimal band broadening

The negligible volume of the WFM-A fraction valve, combined with optimized tubing volumes between the detector and the valve, minimizes band spreading of the fractions. The figure shows that the WFM-A fraction valve peak shape superimposes the straight bypass, whereas the other valves demonstrate much greater dispersion.

The WFM-A effectively collects what you want, when you want it.



Resources

Documents

Documents


Support

Support



Related

Get the demonstrated highest performance available in separations technologies with Waters UPLC/UHPLC systems and detectors for sub 2 micron (high pressure, small particle size) separations for the analytical laboratory.

Protect your Waters LC or LC-MS system investment and ensure optimum productivity and compliance with the range of plans in FlexCHOICE Instrument Service Coverage.

Automates sample purification, including the control of fraction collection as well as sample, fraction and data tracking.

For advanced laboratory data management, including acquisition, processing and reporting for liquid and gas chromatography instruments, equip your lab with the Empower Chromatography Data System (CDS).