Waters Fraction Collector III

Waters Fraction Collector III

Adaptable and reliable fraction collection

Adaptable and reliable fraction collection

Collecting purified material from your liquid chromatography (LC) system, especially in a user-friendly and cost-effective way, can be a challenge.

Waters Fraction Collector III is an easy-to-use, standalone, or software-controlled fraction collector designed for use with high performance liquid chromatography (HPLC) and LC-MS applications. Compatible with flow rates as high as 300 mL per minute, the Fraction Collector III handles a wide range of adapter racks and related collection vessels. Its flexible design accommodates a variety of fraction sizes, whether you are collecting to microtiter plates or multiple containers.

Waters Fraction Collector III. Waters Fraction Collector III

Specifications

Standard test tube (13.0 to 18.0 mm) rack

Eppendorf tube rack

Scintillation vial (16.5 mm) rack

Scintillation vial (27.5 mm) rack

Microtiter plate (4 x 96/384) rack

Preparative funnel (4 x 32 positions) rack

Multipurpose rack

Methods

Time, drop count, drop volume, signal

Nozzle shift time

0.1 s (tube center to center)

Simple mode

Time

99 min 59 s/tube max.

Drop

9999 count/tube max.

Volume

999.9 mL/tube max.

Signal

9999 count/tube max.

Peak mode

End time

999 min max.

Request time

99 min 59 s/tube max.

Monitor time

99 min 59 s/tube max.

Fraction peak

Up to 10 out of 99 peaks

Peak discrimination

Absolute value 100% max.

Slope 100 mV/min or 10 V/min max.

Window mode

Non-window monitor

99 min 59 s max.

No. of windows

10 max.

Start/end time

999 min 59 s max.

Request/monitor time

99 min 59 s/tube max.

Manual mode

Learning response

Chromatogram signal display

High 0.5 s; low 3.0 s

Sampling mode

Playback

Replay results of learning

Interval

99 min 59 s max.

Collection time

99 min 59 s max.

Collection volume

999.9 mL max.

Number of repeats

99 max.

Event markers

2 contact point output circuits

Signal input

10 mV or 1 V full scale

External start input

On start

External end input

On end

External count input

On count

Serial interface

RS-232C (9-pin connector)

Power requirements

100.00 V AC

115.00 V AC

240.00 V AC

0.23 A max.

Local user interface

Operation display

40 characters by 8 rows (LCD w/backlight)

Parameter memory

Battery back-up

Remote control

PC control with MassLynx and Empower 2 Software

External dimensions

Width: 28.60 cm (11.27 in.)

Depth: 35.90 cm (14.14 in.)

Height: 33.50 cm (13.20 in.)

Weight

Approximately 7.00 kg (15.40 lbs)

Temperature range

2 to 40 °C (35 to 104 °F)

Title

Part Number

Waters Fraction Collector III

(Includes one standard rack that holds up to 120 tubes; 12 to 18 mm O.D. x 90 to 180 mm height)

186001878

Diverter valve options

Divert valve assembly, standard

725000142

Divert valve assembly, low volume

(Recommended for microtiter plate rack)

725000143

Fittings kit

(Drop tubes and connecting tubing to accommodate different flow rates)

205000131

Rack options

Microtiter plate rack

(Accepts four microtiter plates, standard, and deep-well)

725000110

Dropper extension nozzle

(Recommended for microtiter plate rack)

725000151

Eppendorf tube rack

(accepts up to 120 eppendorf tubes)

725000145

Title

Part Number

Scintillation vial rack, 16.5 mm

(accepts up to 120 scintillation vials; 16.5 mm O.D. x 54.0 mm height)

725000146

Scintillation vial rack, 27.5 mm

(accepts up to 56 scintillation vials; 27.5 mm O.D. x 57.0 mm height)

725000147

Multipurpose rack

725000113

Preparative funnel adapter rack

(used with preparative funnel adapters – up to four)

725000107

Preparative funnel adapter, 2 per package

(collects up to 32 fractions; requires tubing to connect adapter to collection vessels)

725000106

Tubing for preparative funnel adapter, Tygon 50 feet

WAT037047

Tubing for preparative funnel adapter, Teflon 50 feet

WAT037090

Table-top shelf assembly, for use with prep funnel rack

289000440

Overview

  • Multi-purpose functionality in a small footprint
  • Intuitive keypad and view screen make setup easy
  • Review results in real time, or via a post-run results table
  • Compatible with the LC Prep 150 System, LC Prep AutoPurification System, and Modular Systems
  • Remote management with MassLynx Software for mass spectrometry (MS) applications

Recommended Use: For flexible collection of a variety of fraction sizes, designed for use with HPLC and LC-MS applications.


Features Header

Features Header






Several modes of collection

Fraction Collector III offers several simple to advanced modes of operation for fraction collection, including time, threshold, volume, manual, and sampling. These modes of operation can be combined to allow for advanced fraction collection, such as pooling of repeated runs into common vessels.

Peak detection and collection using an analog detector input from a liquid chromatography (LC) system permits fully automated collection of the peaks of interest. The diverter valve in the system enables you to collect peaks without extraneous solvent and/or unwanted peaks (which are diverted to waste), maximizing fraction collection efficiency and overall preparative LC system productivity.

For maximum control and usability, you can control the Fraction Collector III from a local keypad or through serial port communication by Empower 3 or MassLynx Software.


Integrated instrument control software interface

Control of the Fraction Collector III is accessible through a new instrument control software interface that integrates seamlessly with Empower Software control components. The user can use the interface to configure collection vessels and program collection routines. Real-time feedback from the Fraction Collector III indicates the state of the collection process and the location of the collected fractions.

Multiple collector rack configurations (including custom configurations) accommodate a variety of collection vessels. If the user needs to override collection control, the interface enables software-assisted manual collection through its override function, directly from the instrument control panel.




Resources

Documents

Documents


Support

Support



Related

Achieve fast, efficient, lab-scale separations, and greater throughput with Waters Preparative HPLC Columns, which provide predictable performance and easily scale from analytical to prep.

Protect your Waters LC or LC-MS system investment and ensure optimum productivity and compliance with the range of plans in FlexCHOICE Instrument Service Coverage.
Back To Top Back To Top