Description du produit

The ACQUITY Premier Protein BEH C4 300 Å 1.7 µm, 2.1 x 50 mm columns are QC tested with the MassPREP Protein Mix standard (p/n: 186004900) and are optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. This chemistry is also best for MS sentitivity at low-levels. 2.1mm ID columns are recommended for use with low dispersion (UPLC or UHPLC) systems, especially for LC-MS methods. This column is part of the MaxPeak Premier Class of Columns, which deliver the chromatographic performance expected from our particle technologies while increasing reproducibility, peak shape, and recovery for metal-sensitive analytes.

Note: The same column is also available with the MassPREP Protein Mix Standard at no additional cost (p/n: 176005107).

Suggested use: Low-level intact protein and subunit analysis, phosphorylated proteins

Spécifications

  • Chimie

    C4

  • Mode de séparation

    Phase inverse

  • Particules de support

    Hybrid

  • pH Range Min

    2 pH

  • pH Range Max

    10 pH

  • Temperature Limits

    90 C

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Non

  • Silanol Activity

    Low

  • Molecular Weight Range Max

    150000

  • Particle Shape

    Spherical

  • Granulométrie

    1.7 µm

  • Endfitting Type

    Parker-style

  • Taille des pores

    300 Å

  • QC Tested

    Protein

  • Format

    Colonne Premier

  • Superficie

    90

  • Système

    UHPLC, UPLC

  • Technologie de particules

    BEH

  • Classification USP

    L26

  • Diamètre interne

    2.1 mm

  • Longueur

    50 mm

  • Carbon Load

    8 %

  • eCord

    Oui

  • UNSPSC

    41115711

  • Application

    Protéine

  • Gamme

    ACQUITY

  • Type de produit

    Colonnes

  • Units per Package

    1 pk